Máy Đo – Phân Tích Công Suất – Power Analyzer 4 Channel ZES LMG641

Thông tin sản phẩm

  • Hãng sản xuất: ZES Zimmer
  • Mã sản xuất: LMG641
  • Bảo hành: 24 tháng

Catalog

Duapath Explained

Data sheet sensor

Data sheet LMG test suite

Giá: Liên hệ

Thông tin liên hệ

Yêu cầu báo giá

Sự kết hợp kênh phù hợp cho mọi ứng dụng

Cấu hình với 1 đến 4 kênh đo công suất (thay thế 3 kênh đo và Giao diện tín hiệu xử lý)

Trang bị thêm các kênh có sẵn!

Inverter measurements
1-phase Input
3-phase Output
power measurement
of 3-phase motors
Efficiency measurement
of power supplies
Measuring of core losses

Measurement Channels

L60-CH-A A-Channel for high-precision broadband measurements
High-Precision Channel for power measurements with DualPath functionality, bandwidth DC-10 MHz
best accuracy 0.015% + 0.01%
Measuring inputs and ranges:
1. Voltage directly (V): 3/6/12,5/25/60/130/250/400/600/1000 Vtrms; 3200 Vpk
2. Voltage sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 8 Vpk
3. Current directly (mA): 5/10/20/40/80/150/300/600 and (A): 1.2/2.5/5/10/20/32 Atrms; 120 Apk
4. Current sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 12.5 Vpk
L60-CH-B B-Channel for general purpose measurements
Multi-purpose measurement channel with DualPath functionality, bandwidth DC – 500 kHz
best accuracy 0.05% + 0.02%
Measuring inputs and ranges
1. Voltage directly (V): 3/6/12.5/25/60/130/250/400/600/1000 Vtrms; 3200 Vpk
2. Current directly (mA): 5/10/20/40/80/150/300/600 and (A): 1.2/2.5/5/10/20/32 Atrms; 120 Apk
3. Current sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 12.5 Vpk
L60-CH-C C-Channel for high-precision 50/60 Hz measurements
High-precision measurement channel for 50 Hz applications, bandwidth DC – 10 kHz,
best accuracy 0.03% + 0.01%.
Measuring inputs and ranges:
1. Voltage directly (V): 3/6/12,5/25/60/130/250/400/600/1000 Vtrms; 3200 Vpk
2. Current directly (mA): 5/10/20/40/80/150/300/600 and (A): 1.2/2.5/5/10/20/32 Atrms; 120 Apk
3. Current sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 12.5 Vpk

Options

L6-OPT-DRV Option package for frequency converters
for LMG600 (at least 3 power channels*), consisting of:
– L6-PSI: Process Signal Interface
– L6-SDC: Star-Delta-Conversion
– L6-HRM: Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics)
L6-OPT-TRAFO Option package for transformers
for LMG600 (at least 3 power channels*), consisting of:
– L6-SDC: Star-Delta-Conversion
– L6-HRM: Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics)
L6-OPT-CE-FLK Option Package CE Flicker
for LMG600, consisting of:
– the LMG flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as
– the PC software** LMG Test Suite (LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-3 and EN61000-3-11 for 1-phase and 3-phase* equipment under test
L6-OPT-CE-HRM Option Package CE Harmonics
for LMG600, consisting of:
– the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM) as well as
– the PC software** LMG Test Suite (LMG-TEST-CE-HRM) for analysis of measured values according to EN61000-3-2 and EN61000-3-12 for 1-phase and 3-phase* equipment under test
L6-OPT-CE-HRMFLK Option Package CE Harmonics and Flicker
for LMG600, consisting of:
– the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM),
– internal flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as
– the PC software** LMG Test Suite (LMG-TEST-CE-HRM + LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-2 / EN61000-3-12 and EN61000-3-3 / EN61000-3-11, each for 1-phase and 3-phase* equipment under test
L6-OPT-DVI DVI / VGA Interface
for connection of an external display, beamer, touch device
L6-OPT-PSI Process Signal Interface
8 digital inputs, 8 digital outputs, 2 fast analog inputs (150 kS/s, 15 kHz bandwidth), 8 slow analog inputs (DC), 32 analog outputs, 2 frequency inputs (frequency, orientation, position; DTL, HTL or differential)
L6-OPT-CAN CAN bus interface: find more information here
CAN bus connectivity according to ISO 11898-2 (high-speed CAN)
– bit rate: 5 kbit/s to 1Mbit/s
– galvanic separation at CAN connector: up to 500V
– active support of CAN 2.0A and B standards
– Standard Frame Format or Extended Frame Format for
sending measurement results
– manual polling of measurement values possible via Remote Transmission Request (RTR)
L6-OPT-SDC Star-Delta-Conversion
Minimum requirement LMG600 with at least 3 power channels of the same type
L6-OPT-EVT Event Triggering: find more information here
triggering on crossing voltage or current thresholds recording of 16 tracks with up to 16 million values each
L6-OPT-HRM Harmonic analysis
up to max. 1.000th order (2.000th order with interharmonics) of U, I, P, Q and S, fundamental 3 … 1200 Hz, up to 150 kHz (A channel) resp. 15 kHz (B channel) or 10 kHz (C channel) with anti-aliasing filter, customizable settings for the detection of interharmonics
L6-OPT-FLK Flicker meter according to EN61000-4-15
L6-OPT-SMV Smart Vision
Smart add-on functions for the convenient evaluation of measurements
The package includes:
– Painter: screenshots can be enriched with valuable additional information directly in the GUI before saving
– Env Var Watcher: script-controlled visual watchdog as part of a custom menu
L6-OPT-SPV Sample Value Analysis Module for LMG600
Software* for continuous and gapless streaming of sample values on 16 tracks at a rate of 10 kS/s (up to 1.2 MS/s under optimal conditions), furthermore:
– display of sample recordings in ZLR format
– display of frequency spectrum of recorded sample values
– calculation of RMS values of voltage, current and power
– CSV or MATLAB export of frequency spectrum and RMS values
L6x1-OPT-MSD Mass Storage Device for Measurement Results
Internal mass storage device (SSD) for long-time recording of
measurements. Corresponds to a recording time of more than
600 days with a cycle time (cycle) of 100ms and 100 measurement values

* Note: power analyzer has to be equipped with at least three channels of same type for 3-phase measurements

** System requirements:
– Operating system: Windows 7/8/10 (32/64 bit)
– Hard drive: software: min. 50 MB, data: approx. 20 MB per minute of measurement/phase
– RAM memory: min. 2 GB
– Processor: min. 2 GHz, dual-core
– Interfaces supported: Gbit-Ethernet

Technical Data (Summary), valid for 0 ≤ λ ≤ 1

 

 

 

A channel

Accuracy

 

 

 

± (% of measured value + % of maximum peak value)

 

 

DC DCe) 0.05 Hz … 45 Hz 65 Hz … 3 kHz 45 Hz … 65 Hz 3 kHz … 10 kHz 10 kHz … 50 kHz 50 kHz …  100 kHz 100 kHz …  500 kHz 500 kHz…1 MHz 1 MHz … 2 MHz 2 MHz … 10 MHz
Voltage U* 0.02+0.08 0.02+0.06e) 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.5+1.0 0.5+1.0 f/1 MHz*1.5 + f/1 MHz*1.5
Voltage USENSOR 0.02+0.08 0.02+0.06e) 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.4+0.8 0.4+0.8 f/1 MHz*0.7 + f/1 MHz*1.5
Current I* 5 mA…5 A 0.02+0.1 0.02+0.06e) 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.5+1.0 0.5+1.0 f/1 MHz*1.0 +

f/1 MHz*2.0

–
Current I* 10 A…32 A 0.02+0.1 [1]) – 0.015+0.033) 0.01+0.023) 0.1+0.23) 0.3+0.63) f/100 kHz*0.8 + f/100 kHz*1.23) – – –
Current  ISENSOR 0.02+0.08 0.02+0.06e) 0.015+0.03 0.01+0.02 0.03+0.06 0.2+0.4 0.4+0.8 0.4+0.8 f/1 MHz*0.7 + f/1 MHz*1.5
Power U*/ I* 5 mA…5 A 0.032+0.09 0.032+0.06e) 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.8+1.0 0.8+1.0 f/1 MHz*2.0 +

f/1 MHz*1.8

–
Power U*/ I* 10 A…32 A 0.032+0.092) – 0.024+0.034) 0.015+0.014) 0.104+0.134) 0.4+0.54) f/100 kHz*0.8 +

f/100 kHz*0.84)

f/100 kHz*1.0 +

f/100 kHz*1.14)

– – –
Power U*/ ISENSOR 0.032+0.08 0.032+0.06e) 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.72+0.9 0.72+0.9 f/1 MHz*1.8 + f/1 MHz*1.5
Power USENSOR / I* 5 mA…5 A 0.032+0.09 0.032+0.06e) 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.72+0.9 0.72+0.9 f/1 MHz*1.4 +

f/1 MHz*1.8

–
Power USENSOR / I* 10 A…32 A 0.032+0.092) – 0.024+0.034) 0.015+0.014) 0.104+0.134) 0.4+0.54) f/100 kHz*0.8 +

f/100 kHz*0.84)

f/100 kHz*1.0 +

f/100 kHz*1.04)

– – –
Power USENSOR / ISENSOR 0.032+0.08 0.032+0.06e) 0.024+0.03 0.015+0.01 0.048+0.06 0.32+0.4 0.64+0.8 0.64+0.8 f/1 MHz*1.1 + f/1 MHz*1.5
B channel

Accuracy

    ± (% of measured value + % of maximum peak value)    
DC 0,05 Hz … 45 Hz  65 Hz … 1 kHz 45 Hz … 65 Hz 1 kHz … 5 kHz 5 kHz … 20 kHz 20 kHz … 100 kHz 100 kHz …  500 kHz
Voltage U* 0.1+0.1 0.1+0.1 0.03+0.03 0.2+0.2 0.3+0.4 0.4+0.8 f/1 00 kHz*0.8 +

f/1 00 kHz*1.2

Current I* 5 mA…5 A

Current  ISENSOR

0.1+0.1 0.1+0.1 0.03+0.03 0.2+0.2 0.3+0.4 0.4+0.8 f/1 00 kHz*0.8 +

f/1 00 kHz*1.2

Current I*  10 A…32 A 0.1+0.11) 0.1+0.13) 0.03+0.033) 0.2+0.23) 0.6+1.23) 1.5+1.53) f/1 00 kHz*2.0 +

f/1 00 kHz*2.03)

Power U*/ I* 5 mA…5 A

Power U*/ ISENSOR

0.16+0.1 0.16+0.1 0.05+0.02 0.32+0.2 0.48+0.4 0.64+0.8 f/1 00 kHz*1.28 +

f/1 00 kHz*1.2

Power U*/ I* 10 A…32 A 0.16+0.12) 0.16+0.14) 0.05+0.024) 0.32+0.24) 0.72+0.84) 1.52+1.154) f/1 00 kHz*2.24 +

f/1 00 kHz*1.64)

C channel

Accuracy

    ± (% of measured value + % of maximum peak value)    
DC 0,05 Hz … 45 Hz  65 Hz … 200 Hz 45 Hz … 65 Hz 200 Hz … 500 Hz 500 Hz … 1 kHz 1 kHz … 2 kHz 2 kHz … 10 kHz
Voltage U* 0.1+0.1 0.02+0.05 0.02+0.02 0.05+0.05 0.2+0.1 1.0+0.5 f/1 kHz*1.0 +

f/1 kHz*1.0

Current I* 0.1+0.11) 0.02+0.053) 0.02+0.023) 0.05+0.053) 0.2+0.13) 1.0+0.53) f/1 kHz*1.0 +

f/1 kHz*1.03)

Current  ISENSOR 0.1+0.1 0.02+0.05 0.02+0.02 0.05+0.05 0.2+0.1 1.0+0.5 f/1 kHz*1.0 +

f/1 kHz*1.0

Power 0.16+0.12) 0.032+0.054) 0.03+0.014) 0.08+0.054) 0.32+0.14) 1.6+0.54) f/1 kHz*1.6 +

f/1 kHz*1.04)

Accuracies valid for: 1. Sinusoidal voltages and currents

2. Ambient temperature (23±3) °C

3. Warm-up time 1 h

4. The maximum peak value for power is the product of the maximum peak value for voltage and the maximum peak value for current.

5. 0 ≤ |λ| ≤ 1 (power factor)

6. Current and voltage
10 % … 110 % of nominal value

7. Adjustment carried out at 23 °C

8. Calibration interval 12 months

 
Other values All other values are calculated from current, voltage and power. Accuracy resp. error limits are derived according to context (e.g. S = I * U, ΔS / S = ΔI / I + ΔU / U).  

1) 2) 3) 4) only valid in range 10 … 32 A:

1) additional uncertainty ± 50μA/A2 * Itrms2          2) additional uncertainty ± 50μA/A2 * Itrms2 * Utrms    3) additional uncertainty ± 50μA/A2 * Itrms2        4) additional uncertainty ± 50μA/A2 * Itrms2 * Utrms  

  1. e) Accuracy specification after non-persistent zero adjustment, temperature change after zero adjustment max. ±1°C
Voltage measuring ranges U*
Nominal value (V) 3 6 12.5 25 60 130 250 400 600 1000
Max. trms value (V) 3.3 6.6 13.8 27.5 66 136 270 440 660 1000
Max. peak value (V) 6 12 25 50 100 200 400 800 1600 3200
Overload protection  1000 V + 10 % permanently, 1500 V for 1 s
Input impedance 4.59 MΩ, 3 pF
Earth capacitance < 90 pF
Current measuring ranges I*
Nominal value (A) 0.005 0.01 0.02 0.04 0.08 0.15 0.3 0.6 1.2 2.5 5 10 20 32
Max. trms value (A) 0.0055 0.011 0.022 0.044 0.088 0.165 0.33 0.66 1.32 2.75 5.5 11 22 32
Max. peak value (A) 0.014 0.028 0.056 0.112 0.224 0.469 0.938 1.875 3.75 7.5 15 30 60 120
Input impedance ca. 2.2 Ω ca. 600 mΩ ca. 80 mΩ ca. 20 mΩ ca. 10 mΩ
Overload protection permanent (A) LMG in operation 10 A LMG in operation 32 A
Overload protection short-time (A) 150 A for 10 ms
Earth capacitance < 90 pF
Sensor inputs USENSOR, ISENSOR
Nominal value (V) 0.03 0.06 0.12 0.25 0.5 1 2 4
Max. trms value (V) 0.033 0.066 0.132 0.275 0.55 1.1 2.2 4.4
Max. peak value (V) 0.0977 0.1953 0.3906 0.7813 1.563 3.125 6.25 12.5
Overload protection 100 V permanently, 250 V for 1 s
Input impedance 100 kΩ, 34 pF
Earth capacitance < 90 pF
Isolation All current and voltage inputs are isolated against each other, against remaining electronics and against earth. Max. 1000 V / CAT III resp. 600 V / CAT IV
Synchronization Measurements are synchronized on the signal period. The period is determined based on „line“, „external“, u(t) or i(t), in combination  with configurable filters. Therefore readings are very stable, especially with PWM controlled frequency converters and amplitude modulated  electronic loads.
Scope function Graphical display of sample values over time in two scopes with 8 signals each
Plot function Two time (trend-) diagrams of max. 8 parameters, max. resolution 30 ms
External graphics interface (L6-OPT-DVI) VGA/DVI interface for external screen output
Process signal interface (L6-OPT-PSI) 2 fast analog inputs (150 kS/s, 16 bit, BNC)

8 analog inputs (100 S/s, 16 bit, D-Sub:DE-09)

32 analog outputs (output per cycle, 14 bit, D-Sub: DA-15 & DB-25)

8 switching outputs (6 switches with 2 connections each and 2 switching outputs with common negative, D-Sub: DB-25) 8 switching inputs (150 kS / s, in two groups 4 inputs each with common ground, D-Sub: DB-25) Speed-/torque-/frequency inputs (150 kS/s, D-Sub: DA-15)

Star-delta conversion (L6-OPT-SDC) Conversion of line voltages to phase voltages and computation of resulting active power
Harmonics at device level (L6-OPT-HRM) Harmonics and interharmonics up to 2,000th order
Flicker (L6-OPT-FLK) According to EN 61000-4-15
LMG Remote LMG600 expansion software, basic module for remote configuration and operation via PC
L60-TEST-CE61K LMG600 software for conformity tests according to EN61000 for harmonics and flicker

The complete technical data can be found in the manual, which is stored on your LMG600 in the valid version.

Reviews

There are no reviews yet.

Be the first to review “Máy Đo – Phân Tích Công Suất – Power Analyzer 4 Channel ZES LMG641”

0936.148.348
Zalo: 0936.148.348