Sự kết hợp kênh phù hợp cho mọi ứng dụng
Cấu hình với 1 đến 4 kênh đo công suất (thay thế 3 kênh đo và Giao diện tín hiệu xử lý)
Trang bị thêm các kênh có sẵn!
| Inverter measurements 1-phase Input 3-phase Output |
|
| power measurement of 3-phase motors |
|
| Efficiency measurement of power supplies |
|
| Measuring of core losses |
Measurement Channels
| L60-CH-A | A-Channel for high-precision broadband measurements |
| High-Precision Channel for power measurements with DualPath functionality, bandwidth DC-10 MHz best accuracy 0.015% + 0.01% Measuring inputs and ranges: 1. Voltage directly (V): 3/6/12,5/25/60/130/250/400/600/1000 Vtrms; 3200 Vpk 2. Voltage sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 8 Vpk 3. Current directly (mA): 5/10/20/40/80/150/300/600 and (A): 1.2/2.5/5/10/20/32 Atrms; 120 Apk 4. Current sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 12.5 Vpk |
|
| L60-CH-B | B-Channel for general purpose measurements |
| Multi-purpose measurement channel with DualPath functionality, bandwidth DC – 500 kHz best accuracy 0.05% + 0.02% Measuring inputs and ranges 1. Voltage directly (V): 3/6/12.5/25/60/130/250/400/600/1000 Vtrms; 3200 Vpk 2. Current directly (mA): 5/10/20/40/80/150/300/600 and (A): 1.2/2.5/5/10/20/32 Atrms; 120 Apk 3. Current sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 12.5 Vpk |
|
| L60-CH-C | C-Channel for high-precision 50/60 Hz measurements |
| High-precision measurement channel for 50 Hz applications, bandwidth DC – 10 kHz, best accuracy 0.03% + 0.01%. Measuring inputs and ranges: 1. Voltage directly (V): 3/6/12,5/25/60/130/250/400/600/1000 Vtrms; 3200 Vpk 2. Current directly (mA): 5/10/20/40/80/150/300/600 and (A): 1.2/2.5/5/10/20/32 Atrms; 120 Apk 3. Current sensor input (mV): 30/60/120/250/500 (V): 1/2/4 Vtrms; 12.5 Vpk |
Options
| L6-OPT-DRV | Option package for frequency converters for LMG600 (at least 3 power channels*), consisting of: – L6-PSI: Process Signal Interface – L6-SDC: Star-Delta-Conversion – L6-HRM: Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics) |
| L6-OPT-TRAFO | Option package for transformers for LMG600 (at least 3 power channels*), consisting of: – L6-SDC: Star-Delta-Conversion – L6-HRM: Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics) |
| L6-OPT-CE-FLK | Option Package CE Flicker for LMG600, consisting of: – the LMG flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as – the PC software** LMG Test Suite (LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-3 and EN61000-3-11 for 1-phase and 3-phase* equipment under test |
| L6-OPT-CE-HRM | Option Package CE Harmonics for LMG600, consisting of: – the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM) as well as – the PC software** LMG Test Suite (LMG-TEST-CE-HRM) for analysis of measured values according to EN61000-3-2 and EN61000-3-12 for 1-phase and 3-phase* equipment under test |
| L6-OPT-CE-HRMFLK | Option Package CE Harmonics and Flicker for LMG600, consisting of: – the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM), – internal flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as – the PC software** LMG Test Suite (LMG-TEST-CE-HRM + LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-2 / EN61000-3-12 and EN61000-3-3 / EN61000-3-11, each for 1-phase and 3-phase* equipment under test |
| L6-OPT-DVI | DVI / VGA Interface for connection of an external display, beamer, touch device |
| L6-OPT-PSI | Process Signal Interface 8 digital inputs, 8 digital outputs, 2 fast analog inputs (150 kS/s, 15 kHz bandwidth), 8 slow analog inputs (DC), 32 analog outputs, 2 frequency inputs (frequency, orientation, position; DTL, HTL or differential) |
| L6-OPT-CAN | CAN bus interface: find more information here CAN bus connectivity according to ISO 11898-2 (high-speed CAN) – bit rate: 5 kbit/s to 1Mbit/s – galvanic separation at CAN connector: up to 500V – active support of CAN 2.0A and B standards – Standard Frame Format or Extended Frame Format for sending measurement results – manual polling of measurement values possible via Remote Transmission Request (RTR) |
| L6-OPT-SDC | Star-Delta-Conversion Minimum requirement LMG600 with at least 3 power channels of the same type |
| L6-OPT-EVT | Event Triggering: find more information here triggering on crossing voltage or current thresholds recording of 16 tracks with up to 16 million values each |
| L6-OPT-HRM | Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics) of U, I, P, Q and S, fundamental 3 … 1200 Hz, up to 150 kHz (A channel) resp. 15 kHz (B channel) or 10 kHz (C channel) with anti-aliasing filter, customizable settings for the detection of interharmonics |
| L6-OPT-FLK | Flicker meter according to EN61000-4-15 |
| L6-OPT-SMV | Smart Vision Smart add-on functions for the convenient evaluation of measurements The package includes: – Painter: screenshots can be enriched with valuable additional information directly in the GUI before saving – Env Var Watcher: script-controlled visual watchdog as part of a custom menu |
| L6-OPT-SPV | Sample Value Analysis Module for LMG600 Software* for continuous and gapless streaming of sample values on 16 tracks at a rate of 10 kS/s (up to 1.2 MS/s under optimal conditions), furthermore: – display of sample recordings in ZLR format – display of frequency spectrum of recorded sample values – calculation of RMS values of voltage, current and power – CSV or MATLAB export of frequency spectrum and RMS values |
| L6x1-OPT-MSD | Mass Storage Device for Measurement Results Internal mass storage device (SSD) for long-time recording of measurements. Corresponds to a recording time of more than 600 days with a cycle time (cycle) of 100ms and 100 measurement values |
* Note: power analyzer has to be equipped with at least three channels of same type for 3-phase measurements
** System requirements:
– Operating system: Windows 7/8/10 (32/64 bit)
– Hard drive: software: min. 50 MB, data: approx. 20 MB per minute of measurement/phase
– RAM memory: min. 2 GB
– Processor: min. 2 GHz, dual-core
– Interfaces supported: Gbit-Ethernet








Reviews
There are no reviews yet.